Arming your system – Napco Security Technologies XP-400 User Manual

Page 7

Advertising
background image

Protecting Yourself While at Home

1

Before arming your system, make sure the Green Ready light is ON. This indicates that all of your

protective zones are secure. If any zones are open, the corresponding Zone light will be ON. Secure
those zones before proceeding.

2

Enter your user code. The Green Ready light will go out, and the red Armed light will light.

3

Before your exit delay expires, press

#

to bypass any interior zones, deactivating devices such

as motion sensors, and allowing free movement throughout the premises. The Zone light of any
bypassed zones will flash slowly.

Your system may have been programmed for Automatic Interior Bypass , in which case it will
recognize that you have not left the premises and will automatically bypass any interior zones.

Instant Mode

Pressing

!

followed by

will cancel the Entry delay , activating the “Instant” mode. This is typically

done in the evening when all family members are home for the night. Instant Mode can be activated at any
time after the system has been armed. The Red Armed light will flash rapidly while in the Instant Mode.

Easy Exit (optional)

Your System may have been programmed to allow Easy Exit, which allows a user to exit the premises
with the system armed. By pressing



followed by



, the protection is removed from the Exit/ Entry

zone for 3 minutes. This will allow, for example, an early morning commuter to exit the house in the
morning, without having to disarm and rearm the system, waking the family.

Arming With a System Trouble Present (the

9

System Light is Lit)

If the XP400 has a system trouble present, the

'

'

SYSTEM l

ight will be lit and the keypad sounder

pulsing. If you cannot immediately clear the system trouble, the system can still be armed. Simply

press



to view the trouble, press



again to reset the trouble and then arm the system.

For more information, refer to page12. Note: System troubles should be repaired as soon as possible.

Arming Your System

7

SYSTEM

READY

ZONE 3

ZONE 1

ZONE 2

ZONE 4

ARMED

Oi220a
page 7

Tuesday, September 16, 1997 08:30

Advertising