Niles Audio Personal Emergency Reporting System PERS-2400B User Manual

Page 4

Advertising
background image

2

5. OPTIONAL RELAY OUTPUT CONNECTIONS

7. BACKUP BATTERY

6. OPTIONAL REMOTE SPEAKER/MIC CONNECTIONS

8. INSTALL TRANSFORMER

1

2

3 - RELAY COMMON

4 - RELAY NORMALLY OPEN

5

FORM "A" DRY CONTACT RELAY
24 VOLTS AT 1 AMP MAXIMUM

NOISEMAKER OR

VISUAL INDICATOR

EXTERNAL

POWER SUPPLY

CONSOLE

TERMINAL BLOCK

CONNECT WIRES
TO TERMINALS

ROUTE CABLE UNDER
STRAIN-RELIEF CLAMP

1

TURN POWER
SWITCH OFF

BATTERY TYPE: 12-VOLT, 1.2 AMP/HOUR

CONNECT RED LEAD TO
POSITIVE AND BLACK LEAD TO
NEGATIVE BATTERY TERMINAL

FIT BATTERY
INTO CONSOLE

SLIDE DOWN

THEN BACK

OFF

ON

2

3

1

PLUG TRANSFORMER
INTO AN UN-SWITCHED
117 VAC OUTLET

SECURE
TRANSFORMER
WITH SCREW

2

1 - EXTERNAL SPEAKER

EXTERNAL SPEAKER

3 - RELAY COMMON

4 - RELAY NORMALLY OPEN

5 - DIALER POWER

CONSOLE

TERMINAL BLOCK

VB-4B TERMINAL BLOCK

EXTERNAL MICROPHONE (+)

MICROPHONE COMMON (-)

CONSOLE MICROPHONE (+)

LINEAR
MODEL RSM-1

RSM-1 TERMINAL BLOCK

SPKR

SPKR

MIC (-)

MIC (+)

VB-4B
VOICE
BOARD

RSM-1

TERMINALS

NOTE: REMOVE
JUMPER WHEN

USING AN

EXTERNAL SPKR

NOTE: NOT

TESTED BY UL

DIALER COMMON

2 -

REMOVE

JUMPER

WIRE

USE

SHIELDED

TWISTED PAIR

WIRE FOR

MICROPHONE

Advertising