Lifebreath MAXTOP User Manual
Page 17

17
Press and hold the fan selection button on the Control Pad. After 5 seconds the control will begin to cycle each
mode holding each for 2 seconds. Release the button when the desired mode of operation is reached.
Modes of Operation
LED Indication
OFF
No LED’s illuminated
HRV/ERV is off, no controls will initiate operation.
ON/STANDBY
Steady Green LED and Yellow LED to indicate speed
HRV/ERV will run at speed selected in ventilation mode. Standby mode
is indicated by no speed indicator illuminated. Optional remote controls
will override standby or selected speed into high speed.
20 ON / 40 OFF
Flashing Green LED and Yellow LED to indicate speed.
HRV/ERV will operate in ventilation mode at speed selected for 20 min-
utes and OFF for 40 minutes.
RECIRCULATION
Steady Red LED and Yellow LED to indicate Speed.
*Note: Not available on all models
HRV/ERV will operate in recirculate mode at the selected speed. Optional
remote controls will override unit into high speed ventilate mode.
20 ON / 40 RECIRCULATE
Flashing Orange LED and Yellow LED to indicate speed.
*Note: Not available on all models
HRV/ERV will operate in ventilation mode at speed selected for 20 min-
utes and recirculation mode for 40 minutes.
To select speed
Momentarily press fan selection button and release. HRV/ERV will move into next speed. OFF is indicated by no
yellow LED illuminated. Speed 1 is the first yellow LED. Speed five is indicated by a flashing speed 4 LED.
Automatic Defrost
During cold outdoor conditions the HRV/ERV will occasionally go into an automatic defrost function, which will pre-
vent ice from forming on the core. Defrost is indicated by a flashing Red LED indicator.
Which Mode of Operation is Best for Me?
BEST
Continuous low
Ensures continuous air exchange within the home.
speed operation
Air is always fresh and healthy.
Intermittent low
Provides 20 minutes air exchange and 40 minutes off.
BETTER
speed operation
20 ON / 40 OFF
20 ON/40 RECIRCULATE
Provides 20 minutes air exchange and 40 minutes
recirculation.
GOOD
Standby mode
Allows unit to run on demand from remote controls such as
DET Timer and Dehumidistat.
To Select Mode of Operation for ControlAir 15