Regulator, English – Nostalgia Electrics KRS-2150 User Manual

Page 10

Advertising
background image

ENGLISH

8

REGULATOR

The Double Regulator works the CO2 Tank and measures PSI (pounds

per square inch), as well as the volume of the CO2 gas in the Cylinder.

Set Output Pressure Gauge between 8-12 PSI for a nice, frothy head.

Close the Shut Off Valve on the Double Regulator, and

1.

open the CO2 Tank Valve (#9) completely.
Unlock Screw using Allen Wrench (included). Slowly turn the Double

2.

Regulator adjustment screw until the desired pressure is shown on the
Output Pressure Gauge (8-12 PSI). Turning clockwise will increase the output
pressure, and turning counter-clockwise will decrease the output pressure.

Once desired pressure is reached, you may re-lock Screw using Allen Wrench.

3.

Open the

4.

CO2 Shut Off Valve on the Double Regulator to allow gas flow

from the Double Regulator to the Keg Coupler. You will hear the keg

pressurizing. The output needle will drop momentarily until the pressure
has equalized. Then the needle will return to the point you set it at.

The Keg Coupler is designed with a pressure relief valve (PRV).

5.

Pull the ring on the PRV briefly to allow gas to vent. This will
permit gas to flow through the Double Regulator and help obtain
a more accurate reading on the Output Pressure Gauge.

Re-check the output pressure on the Double Regulator, and if necessary

6.

re-adjust using step #2 until the desired pressure is shown. It is always
wise to follow up any adjustment to the Double Regulator with a
brief pull of the PRV ring to ensure an accurate output reading.

Tank

Pressure

Gauge

(0-3000 PSI)
for measuring

PSI of CO2

in tank.

Output

Pressure

Gauge

(0-60 PSI) for
measuring PSI
of CO2 outflow

from Tank to Keg

(8-12 PSI
recommended).

Screw adjusts

the output

pressure.

Pressure Relief Valve

CO2 Shut Off

Valve (shown in

open position)

Advertising