Pump component identification, Operation instructions – North Star M157300E User Manual

Page 11

Advertising
background image

Pump Component Identification

11

157300

157301 & 157302

FIG02309
















Operation Instructions


Water Supply
1.) Make sure the water supply is clean. Debris can cause excess pump wear and reduce

performance.

2.) An insufficient water supply will damage your pump. Make sure the water supply is steady and is

20% over the rated flow of your pump. Use a stopwatch to time how long it takes to fill a 5 gallon
bucket with your garden hose. The bucket must fill faster than the times listed in the table below.

Model

Time to fill 5 gallon bucket

157300 150

seconds

157301 160

seconds

157302 96

seconds


3.) The water supply garden hose must have an inside diameter of at least 5/8”. If the hose is more

than 100 ft. long, the diameter must be at least 3/4”.

4.) Never use a reservoir tank as a water source. Drawing water out of a tank may cause pump

cavitation and damage to your pump. This pressure washer is designed for a pressurized water
source such as a city water faucet. However, the water source pressure must not exceed 115 psi
(8 bar).

5.) Always use a flexible rubber hose for your water supply. Do not use rigid piping.

Advertising