Interconnection cable wiring method, Technical specifications – Network Technologies UNIMUX-USBV-2 User Manual

Page 8

Advertising
background image

NTI XTENDEX USB EXTENDER

5

INTERCONNECTION CABLE WIRING METHOD

The connection cable between the remote and local is terminated with RJ45 connectors and must be wired according to the
EIA/TIA 568 B industry standard. Wiring is per the table and drawing below.

Pin

Wire Color

Pair

Function

1

White/Orange

2

T

2

Orange

2

R

3

White/Green

3

T

4

Blue 1

R

5

White/Blue

1

T

6

Green 3

R

7

White/Brown

4

T

8

Brown 4

R

Figure 5- View looking into RJ45 female

TECHNICAL SPECIFICATIONS

USB to host CPU

USB Type B female

USB to device

USB Type A female

USB output power

5V, 1.4A for 4 ports (<500mA per port)

Interconnect Cable

CAT5/5e Solid/Stranded UTP/STP; CAT6 Solid UTP/STP ; CAT6a Solid UTP;

CAT7 Solid STP EIA/TIA 568 B wiring

Remote Unit Power

100V to 240V at 50 or 60Hz-5VDC/3.0A via AC adapter

Local Unit Power

Powered by CPU

Operating temperature

32°F to 122°F (0°C to 50°C)

Storage temperature

-20°F to 140°F (-30°C to 60°C)

Operating and Storage Relative Humidity

0 to 90% non-condensing RH

Size (In.) WxDxH

5.1x3.1x1.2

Regulatory Approvals

RoHS, CE

Distances for CAT5/CAT5e, CAT6 and CAT7 Cables

CABLE

DISTANCE (feet)

CABLE

DISTANCE (feet)

CAT5/5e

Solid UTP/STP

200

CAT6

Solid UTP/STP

200

CAT5/5e

Stranded
UTP/STP

100

CAT6a

Solid UTP

195

(Distance Includes
10ft patch cable at

each end)

CAT7

Solid STP

200

Longer lengths of CATx cable are not recommended.