PRECAUTIONS
Within a partial enclosure which includes an 
overhead cover and three side walls, as long as 
30 percent or more of the horizontal periphery of 
the enclosure is permanently open.
This appliance requires 16.4oz (1lb) LP_gas 
supply cylinder.
The LP-gas supply cylinder to be used must be:
Constructed and marked in accordance with the 
Specifications for LP-gas cylinders of the U.S.
Department of Transportation (DOT); or the 
Standard for Cylinders, Spheres and Tubes for 
Transportation of Dangerous Goods and Com-
mission, CAN/CSA-B339, as applicable;
Provided with a listed overfilling prevention 
device; and provided with a cylinder connection 
device compatible with the connection for the 
appliance.
The cylinder be disconnected when the appli-
ance is not is use.
Storage of an appliance indoors is permissible 
only if the cylinder is disconnected and removed 
from the appliance.
A cylinder must be stored outdoors in a well-
ventilated area out of the reach of children. A 
disconnected cylinder must have dust caps 
tightly installed and must not be stored in a build-
ing, garage or any other enclosed area.
Do not store a spare LP-gas cylinder under or 
near this appliance;
Never fill the cylinder beyond 80 percent full;
Do not clean the heater with cleaners that are 
combustible or corrosive.
NOTE:PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
Place the dust cap on the cylinder valve outlet 
whenever the cylinder is not in use. Only install 
the type of dust cap on the cylinder valve that is 
provided with the cylinder valve. Other types of 
caps or plugs may result in leakage of propane.