Leak testing instructions, Warning – Napoleon Grills BIPRO 450 User Manual

Page 23

Advertising
background image

23

www.napoleongrills.com

Leak Testing Instructions

WARNING!

A leak test must be performed annually and each time a cylinder is hooked up or if a part

of the gas system is replaced.

WARNING!

Never use an open flame to check for gas leaks. Be certain no sparks or open flames are

in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to

property, serious bodily injury, or death.

Leak testing: This must be done before initial use, annually, and whenever any gas components are replaced or

serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing Diagram

for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose,

manifolds and valves.

Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended

by the Napoleon Customer Care department and have the grill inspected by a certified gas installer.

If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspected

by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.

Advertising