General information, Gas hook-up instructions, Propane cylinder specifications – Napoleon Grills BIPRO 450 User Manual

Page 4: Warning

Advertising
background image

4

www.napoleongrills.com

General Information

This Gas Barbecue Is Certified Under Canadian And American National Standards, CSA 1.6-2007 and

ANSI Z21.58-2007 respectively for Outdoor Gas Grills and should be installed to conform with local codes. In

absence of local codes, install to the current CAN/CSA-B149.1 Propane Installation Code in Canada or to the

National Fuel Gas Code, ANSI Z223.1 in the United States.
If a rotisserie motor is used, it must be electrically grounded in accordance with local codes or, in absence of

local codes, with the current CSA C22.1 Canadian Electrical Code in Canada or the National Electrical Code,

ANSI/NFPA 70 in the United States.
CALIFORNIA PROPOSITION 65: The burning of gas fuel creates by-products, some of which are on the list as

substances known by the State of California to cause cancer or reproductive harm. When cooking with gas,

always ensure adequate ventilation to the unit, to minimize exposure to such substances.

Propane Cylinder Specifications

WARNING!

If these instructions are not followed exactly, a fire causing death or serious injury may

occur.

A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never use a

cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in accordance

with the specifications for LP-gas cylinders of the National Standard of Canada, CAN/CSA-b339, Cylinders,

Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable or the Specifications

for LP-Gas Cylinders of the U.S. Department of Transportation (D.O.T.). This appliance has been designed for

use with a 20 lb. (9.1 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a cylinder connection device compatible with the connection

for outdoor cooking appliances. The propane cylinder must be provided with a shut-off valve terminating in

a propane cylinder valve type QCC1, and a safety relief device having direct communication with the vapor

space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the cylinder

shall include a collar to protect the cylinder valve. The cylinder shall incorporate a listed OPD (overfill protection

device). Do not store a spare LP-gas cylinder under or near this appliance. Never fill the cylinder beyond

80 percent full.
Use only the pressure regulator and hose assembly provided with this barbecue. Replacement pressure

regulators and hose assemblies must be specified by the manufacturer. Do not store a spare propane cylinder

on the shelf beneath the barbecue.
The regulator supplies a pressure of 11 inches. water column to the gas grill and has a QCC1 type fitting.

Cylinders to be used with this unit must be supplied with a QCC1 cylinder valve. A QCC1 cylinder has a

positive seating connection, which will not allow gas flow until a positive seal has been achieved. It is also

equipped with an excess flow device. In order to attain full flow to the grill, the valves must be in the off

position when the cylinder valve is turned on.

Gas Hook-Up Instructions

WARNING!

This grill is designed for non-combustible enclosures only, and must be installed and

serviced by a qualified installer to local codes.

WARNING!

Cabinet frame, cabinet, and counter top must be made from non-combustible material.

BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping

should be located as shown in the built-in instructions. A flexible metal connector is included to simplify the

installation of the unit. Connect this flexible metal connector to the flare fitting on the end of the manifold.

Connect the other end of the connector to the gas piping. Ensure that the connector does not pass through a

wall, floor, ceiling or partition, and is protected from damage. Do not use a hose to connect the unit except to

connect the cylinder regulator to the piping system. It must be connected with rigid pipe, copper tube or an

approved flexible metal connector which complies with Z21.4 /CSA 6.10.
The installation must comply with CAN B149.1 Natural Gas and Propane installation code in Canada, or to the

National Fuel Gas code, ANSI Z223.1 in the United States. The gas supply pipe must be sufficiently sized to supply

Advertising