Possibilities for insertion

Kitchen unit with door

The panel installed below the hob must be easy
to remove and let an easy access in case a
technical assistance intervention is necessary.

min 20 mm

(max 150 mm)

30 mm

60 mm

b

a

a) Removable panel

b) Space for connections

Kitchen unit with oven

The hob recess dimensions must obey the indi-
cation and the kitchen unit must be equipped
with vents to let a continuous supply of air. The
electrical connection of the hob and the oven
must be installed separately for safety reasons
and to let easy remove oven from the unit.

50 cm

2

360 cm

2

180 cm2

120 cm

2

Product description

Cooking surface layout

1

2

3

4

180

mm

145

mm

1

Rear cooking zone 1700 W

2

Front cooking zone 1200 W

3

Power indicator

4

Control knobs