8 measurements, Measurements – Nokia DNT2Mi sp/mp User Manual

Page 43

Advertising
background image

Commissioning DNT2Mi

DN01145897

© Nokia Corporation

43 (128)

Issue 2-0 en

Nokia Proprietary and Confidential

Note

6.8

Measurements

After all the settings have been checked, we recommend that you carry out a line
quality and a BER test.

Before starting the BER test, reset all statistics and error counters. Read statistics
and error counters after the BER test.

Noise margins, Rx and Tx line levels, and attenuations (Q1: 7,1...3)

Establish a link between two units. After the line is up, check the noise margin,
Rx level, and line attenuation from the Measurements menu.

You can use Table 28 in Appendix A to mark down the results for line
attenuation.

Bit error rate test

We recommend you to perform a five-minute bit error rate (BER) test. For the
test, you need an external test equipment.

You can use Table 27 in Appendix A to mark down the results.

After the tests

Check that all alarms have disappeared and the statistics are still correct.

Table 3.

Monitoring a line

Tx level

Line 1 or 2: xx dBm

xx = +7.5 to +14.5 dBm

Rx level

Line 1 or 2: xx dBm

xx = +14.5 to -26 dBm

Noise margin

Line 1 or 2: xx dB

xx = 0 to +15 dB

Attenuation

Line 1 or 2: xx dB

xx = 0 to 41 dB

Advertising