Napa Essentials Napa 85-300A User Manual

Page 7

Advertising
background image

• 7 •

cables. The output leads of the charger are terminated with 3/8"

(9.5 mm) dia. ring terminals. Remove the bolt from the battery

post connector, insert the bolt through the ring terminal then place

the bolt back in the battery connector and tighten. Connect the

POSITIVE (RED) ring terminal from the battery charger to the

POSITIVE (POS, P, +) ungrounded post of the battery. Connect

the NEGATIVE (BLACK) ring terminal to the vehicle chassis

or engine block away from the battery. Do not connect the ring

terminal to the carburetor, fuel lines, or sheet-metal body parts.

Connect to a heavy gauge metal part of the frame or engine block.

6.6 For positive-grounded vehicle: You should disconnect both battery

cables from the battery before connecting the charger cables. The

output leads of the charger are terminated with 3/8" (9.5 mm) dia.

ring terminals. Remove the bolt from the battery post connector,

insert the bolt through the ring terminal then place the bolt back

in the battery connector and tighten. Connect the NEGATIVE

(BLACK) ring terminals from the battery charger to the NEGATIVE

(NEG, N, –) ungrounded post of the battery. Connect the

POSITIVE (RED) ring terminals to the vehicle chassis or engine

block away from the battery. Do not connect the ring terminals to

the carburetor, fuel lines, or sheet-metal body parts. Connect to a

heavy gauge metal part of the frame or engine block.

6.7 Connect the charger AC supply cord to the electrical outlet.

6.8 When disconnecting the charger, disconnect the AC cord, remove

the ring terminal from the vehicle chassis, and then remove the

ring terminal from the battery terminal.

7. FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE

VEHICLE.

A SPARK NEAR THE

BATTERY MAY CAUSE A

BATTERY EXPLOSION. TO

REDUCE THE RISK OF A

SPARK NEAR THE BATTERY.

7.1 Check the polarity of the

battery posts. The POSITIVE (POS, P, +) battery post usually has a

larger diameter than the NEGATIVE (NEG, N, -) post.

7.2 Attach at least a 24-inch (61 cm) long 6-gauge (AWG) (13 mm

2

)

insulated battery cable to the NEGATIVE (NEG, N, -) battery post.

Advertising