NTI NODEMUX SERIES UNIVERSAL KVM SWITCH

13

ON

OFF

1 2 3 4 5 6 7 8

Dipswitches

The dipswitches located next to the RS232 connection (Fig. 8) are used to configure the baud
rate and address of the NODEMUX. The default baud rate is 9600. The default address is 1.
Use the charts below to change the baud rate and address as needed.

Figure 17- RS232 Dipswitches

RS232 Interface Test Program

RS232 communication is configured using the RMTEST program, located on the supplied floppy disk. This software allows a
user to test the functions of an NTI NODEMUX or Multi-user/Multi-platform switch RS232 interface. The RMTEST program
generates a main menu with the 3 selections described below:

MAIN OPTIONS

1. Matrix Options

- send commands to the unit.

2. Setup Options

- set COM port, baud rate, and unit address

3. Quit

- quit the program

DIP SWITCH
The unit powers up with a default
baud rate of 9600 and a fixed data
protocol of 8 data bits, no parity, and
1 stop bit. To change the baud rate,
unit address, and loop back (more on
the unit address and loop back later),
an 8-SPST DIP switch on the panel
near the DB-9 connectors can be
used. This table shows the DIP switch
functions and their default positions.

SWITCH FUNCTION

DEF-
AULT

1

loop back

ON

2

baud rate 0

ON

3

baud rate 1

ON

4

baud rate 2

ON

5

unit address 0

ON

6

unit address 1

OFF

7

unit address 2

OFF

8

unit address 3

OFF

BAUD RATE
The baud rate can be
changed by powering
down the unit,
changing the DIP
switch, and then
powering back up.
This table shows how
to set the baud rate.

DIP SWITCH

BAUD
RATE

4

3

2

OFF

OFF

OFF

300

OFF

OFF

ON

600

OFF

ON

OFF

1200

OFF

ON

ON

2400

ON

OFF

OFF

4800

ON

OFF

ON

9600

ON

ON

OFF

9600

ON

ON

ON

9600

DIP SWITCH

UNIT ADDRESS

8

7

6

5

OFF

OFF

OFF

OFF

0 (not valid)

OFF

OFF

OFF

ON

1

OFF

OFF

ON

OFF

2

OFF

OFF

ON

ON

3

OFF

ON

OFF

OFF

4

OFF

ON

OFF

ON

5

OFF

ON

ON

OFF

6

OFF

ON

ON

ON

7

ON

OFF

OFF

OFF

8

ON

OFF

OFF

ON

9

ON

OFF

ON

OFF

10

ON

OFF

ON

ON

11

ON

ON

OFF

OFF

12

ON

ON

OFF

ON

13

ON

ON

ON

OFF

14

ON

ON

ON

ON

15

UNIT ADDRESS
To allow multiple units to be controlled from a single host
port, the remote interface is designed to allow "daisy
chaining" of up to 15 units. By setting the appropriate
DIP switches, each unit can be given a unique address
(1-15). Then the unit will only respond to commands on
the bus if its address is embedded in the command. The
"loop back" DIP switch should be ON for the last unit in
the chain, and OFF for all other units. If only one unit is
being controlled, DIP switch 1 should be left ON. This
table shows how to set the unit address.