Step description – Niles Audio MSU140 User Manual

Page 10

Advertising
background image

9

I

N

F

R

A

R

E

D

M

A

I

N

S

Y S T

E

M

U

N

I

T

STEP

DESCRIPTION

1. Connect and test the

power supply. If it tests
OK, unplug the connector
from the power socket
and proceed.

A) Plug the supplied 12vDC power supply into an unswitched

120V AC outlet, 50-60 HZ .

B) Plug the connector into the socket marked “Power” on the

MSU140.

C) If the Power LED does not light, test the unswitched 120

VAC outlet, 50-60 HZ with another appliance. If the outlet
tests OK, you have a defective power supply which must be
replaced for you to continue.

2. Connect the Sensor/

Keypad cable the Sensor
input.

A) Strip 1/4" of insulation from the end of each wire. Tightly

twist the end of each wire until no frayed ends remain.

B) Use a small flathead screwdriver or your thumbnail to raise the

locking tabs, exposing the holes on the removable connectors.

C) Insert each wire into the appropriate hole on the removable

connector plug (Figure 6), and snap the locking tab down.
To help you, the connector plug is keyed. Insert the smooth
side of the connector plug into the smooth side of the sock-
et. Don’t force the scalloped side of the connector plug into
the smooth side of the socket.

DS00329BCN-MSU140-1.qxp 8/17/05 11:26 AM Page 9