The dipswitches located next to the RS232 connection (Fig. 8) are used to configure the baud rate and
address of the KEEMUX. The default baud rate is 9600. The default address is 1. Use the charts
below to change the baud rate and address as needed.








DIP SWITCH

The unit powers up with a default
baud rate of 9600 and a fixed data
protocol of 8 data bits, no parity, and
1 stop bit. To change the baud rate,
unit address, and loop back (more on
the unit address and loop back later),
an 8-SPST DIP switch on the panel
near the DB-9 connectors can be
used. This table shows the DIP switch
functions and their default positions.

SWITCH FUNCTION

DEF-
AULT

1

loop back

ON

2

baud rate 0

ON

3

baud rate 1

ON

4

baud rate 2

ON

5

unit address 0

ON

6

unit address 1

OFF

7

unit address 2

OFF

8

unit address 3

OFF

BAUD RATE

The baud rate can be
changed by powering
down the unit,
changing the DIP
switch, and then
powering back up.
This table shows how
to set the baud rate.

DIP SWITCH

BAUD
RATE

4

3

2

OFF OFF

OFF 300

OFF OFF

ON 600

OFF ON OFF 1200
OFF ON ON 2400
ON OFF

OFF

4800

ON OFF

ON 9600

ON ON

OFF

9600

ON ON

ON 9600

DIP SWITCH

UNIT ADDRESS

8

7

6

5

OFF

OFF

OFF

OFF

0 (not valid)

OFF

OFF

OFF

ON

1

OFF OFF

ON OFF 2

OFF OFF

ON ON

3

OFF ON OFF OFF 4
OFF ON OFF ON 5
OFF ON ON OFF 6
OFF ON ON ON 7
ON OFF

OFF

OFF

8

ON OFF

OFF

ON 9

ON OFF

ON OFF

10

ON OFF

ON ON 11

ON ON

OFF

OFF

12

ON ON

OFF

ON 13

ON ON

ON OFF

14

ON ON

ON ON 15

UNIT ADDRESS
To allow multiple units to be controlled from a single host
port, the remote interface is designed to allow "daisy
chaining" of up to 15 units. By setting the appropriate
DIP switches, each unit can be given a unique address
(1-15). Then the unit will only respond to commands on
the bus if its address is embedded in the command. The
"loop back" DIP switch should be ON for the last unit in
the chain, and OFF for all other units. If only one unit is
being controlled, DIP switch 1 should be left ON. This
table shows how to set the unit address.