CLEANING AND MAINTENANCE (CONT.)

Replacing Filters

Replacing UV Lamp

The life span of UV lamp is about 5,000 hours. Replace UV lamp when it is damaged or when no blue light is observed.

Remove the Front Face Plate, Washable Pre-Filter, Washable Plasma Dust Filter, and HEPA/Charcoal filter before replacing
the UV lamp (refer to page 7 on how to dissemble).

Softly twist the UV lamp, remove the lamp from its position, and insert a lamp tube of the same model.

Resetting the CLEAN METAL GRID and REPLACE FILTER Indicators

Please change filter when the

FILTER

REPLACE

indicator is glowing.

Note: Please refer to page 7 for instructions on

filter installation and removal.

1. CLEAN METAL GRID Indicator

How to Reset:

When the unit is plugged in, but turned off, the resetting

process for the CLEAN METAL GRID indicator is done by

pushing both the RESET and the TIMER buttons at the

same time.

2. REPLACE FILTER Indicator

When the unit is plugged in, but turned off, the resetting

process for the REPLACE FILTER indicator is done by

Pushing both the RESET and the FLOW buttons

at the same time.

After cleaning and replacing filters, reset the CLEAN METAL GRID and REPLACE FILTER indicators.
Otherwise the two indicators will remain on after servicing the unit.

The unit must be plugged but turned off to reset the CLEAN METAL GRID and REPLACE FILTER indicators.
The RESET button is inside the unit (cannot be reached with finger).

Please use a toothpick, straightened paper clip or other similar shaped object to push the RESET button.