The Nortec MH Series is available in two basic
versions. The

flOw

model with direct water drainage

and the

REflow

model for water recirculation.

Whether to use a flow or REflow system depends
considerably on the primary application of humidifying
or cooling and the supplied water quality.

The

REflow

model contains a circulation pump that

conveys the water via EPDM plastic hose to the spray
beam located above the humidifier box. The water
then trickles vertically through the boxes. The water
not needed for humidifying flows back into the water
basin where it is collected and recuirculated for
optimal water efficiency.

In the

flOw

model, the water is not collected in the

water basin, but is discarded and flows directly into
the drain.

5

features Comparison

MHB

flow

MHTC

flow

MHB

REflow

MHTC

REflow

Operates on DI/RO, Potable, Soften Water

Circulation Water System

Direct Water System

Total Control (TC) System with Full Backlit Display

On/Off control system

Smart Water Management System

Adjustable Flush Cycles

Pre-cleaning Sequence

Smart Media Box Drying

Modbus BMS host protocol

Programmable Maintenance Settings

Step-Control 1, 2 or 3 Stage

Multi-Unit Networking

Display and Control of RH

Multiple Control Signal Acceptance

Operation History Log

Real Time Information

Adjustable Capacity of Nominal Output

Remote Fault Indication

Stainless Steel Reservoir

Stainless Side frames

V-Profile Polyester Media

Mist Eliminator V-Profile Polyester Media (above 750 fpm)

2 Year Limited Warranty *Excluding Media

Conductivity Smart Monitoring

º

Ultra Violet Water Treatment

º

º

º

º

Nortec LINKS BMS Interoperability -
BACnet, Lon Talk, Modbus

º

º

Nortec OnLine - Internet Monitoring and Control

º

º

Ultra Violet Sterilization

For applications where higher hygienic requirements must be met an optional UV
package is available. The ultra violet radiation from the discharge lamp sterilizes the
water and controls potential microbial build up. Both Flow and REflow models can
be fully equipped.

Conductivity Monitoring

Conductivity monitoring will continuously check the Total Dissolved Solid (TDS)
content inside the water tank. The adjustable conductivity sensor then initiates
drains accordingly. This feature is available for the REflow models only.

Controls

Nortec offers a wide range of digital controls when selecting the MH product.
The total controller allows easy integration into any local building management
system with it’s host protocol modbus. See Nortec LINKS2 and Online for other
communication options.