COMMAND:

*

zone xx MUTE OFF (returns zone output to currently connected source at previous volume

setting).

RESPONSE:

*********************************************************************************
COMMAND:

*

zone xx BASS EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.

USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10.

RESPONSE:

NOTE: sending this command to the E6D will override the non-volatile BASS setting (set from keypad) for this zone until power
is cycled.

*********************************************************************************
COMMAND:

*

zone xx TREBLE EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.

USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10.

RESPONSE:

NOTE: sending this command to the E6D will override the non-volatile TREBLE setting (set from keypad) for this zone until
power is cycled.

*********************************************************************************
COMMAND:

*

zone xx SOURCE GROUP ON.

RESPONSE:

NOTE: sending this command to the E6D will override the non-volatile GROUP setting (set from keypad) for this zone until
power is cycled.

*********************************************************************************
COMMAND:

*

zone xx SOURCE GROUP OFF.

RESPONSE:

NOTE: sending this command to the will override the non-volatile GROUP setting (set from keypad) for this zone until power is
cycled.

*********************************************************************************
COMMAND:

*

zone xx VOLUME RESET ON.

RESPONSE:

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP
switches) for this zone until power is cycled.

*********************************************************************************
COMMAND:

*

zone xx VOLUME RESET OFF.

RESPONSE:

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP
switches) for this zone until power is cycled.

*********************************************************************************
COMMAND:

*

zone xx KEYPAD LOCK ON This will INHIBIT ANY keypad control input on the zone. This is

the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three
seconds).

RESPONSE:

#

ZxxMTOFF<CR>

Same response as for *ZxxCONSR<CR>

ZxxBASSyyy<CR>

Same response as for *ZxxSETSR<CR>

ZxxTREByyy<CR>

Same response as for *ZxxSETSR<CR>

ZxxGRPON<CR>

Same response as for *ZxxSETSR<CR>

ZxxGRPOFF<CR>

Same response as for *ZxxSETSR<CR>

ZxxVRSTON<CR>

Same response as for *ZxxSETSR<CR>

ZxxVRSTOFF<CR>

Same response as for *ZxxSETSR<CR>

ZxxLKON<CR>

ZxxLKON<CR>6