Network Technologies NTI VOPEX VOPEX-C5SV-x User Manual

Page 13

Advertising
background image

10

Interconnection Cable Wiring Method

The connection cable between the VOPEX-C5SVA-x and each ST-C5SVA-R-600 Receiver is terminated with
RJ45 connectors and must be wired according to the EIA/TIA 568B industry standard. Wiring is as per the
table and drawing below.

Pin

Wire Color

Pair

Function

1

White/Orange

2

T

2

Orange

2

R

3

White/Green

3

T

4

Blue

1

R

5

White/Blue

1

T

6

Green

3

R

7

White/Brown

4

T

8

Brown

4

R

Figure 7- View looking into RJ45 female

Troubleshooting

Each and every piece of every product produced by Network Technologies Inc is 100% tested to exacting
specifications. We make every effort to insure trouble-free installation and operation of our products. If
problems are experienced while installing this product, please look over the troubleshooting chart below to see if
perhaps we can answer any questions that arise. If the answer is not found in the chart, please check the
FAQs (Frequently Asked Questions) at our website at http://www.nti1.com or contact us directly for help at 1-
800-742-8324 (800-RGB-TECH) in US & Canada or 1-330-562-7070 worldwide. We will be happy to assist in
any way we can.

Problem

Cause

Solution

VOPEX-C5SVA-x or ST-
C5SVA-R-600 power
LED does not illuminate

• A power supply is not

connected or plugged-in.

• Make sure each outlet is live and the AC adapters

are plugged-in. (one for each Remote and one for
the VOPEX-C5SVA-x)

• Make sure power connectors are fully connected to

their ports.(pg 7)

No video on display

• One or more video cables is

loose or disconnected.

• No power to the VOPEX-

C5SVA-x or the ST-C5SVA-R-
600 Receiver.

• Video Cable was not attached

when CPU was booted.

• CAT5 cable is not connected.

• Check all video cable connections

• Make sure power LEDs are illuminated for local

and remote. If not, see solution for problem above.

• With all the cables properly connected, reboot the

CPU.

• Check cable connections. Make sure they are

snapped-in properly and completely and reboot.

T

1
+

R

2
-

T

3
+

R

4
-

T

5
+

R

6
-

T

7
+

R

8
-

Pair 2

Pair 1

Pair 4

Pair 3

Interconnection Cable Wiring Method