5 earth the 10 kw scanner – NorthStar Navigation 10 kW User Manual

Page 25

Advertising
background image

You can connect the radar processor to either the Northstar 6100i OR to the Northstar 8000i, but not
to both simultaneously.

10 kW radar processor interface connectors

Connector name

Connector function

Connects to...

Network

Ethernet communications for
the 8000i

8000i network, using the 8000i
network cable (NS00481X)

Power (+Ve and -Ve)

Power input

Ship's power 24 V DC ONLY (using
the power cable)

NMEA / Comms

Data communications (for the
6000i and 6100i systems
only)
Remote power control, relay
and ignition (for the 6000i,
6100i, and 8000i)
NMEA communications for
compass (for the 8000i only).

6000i or 6100i display unit, using
radar communications cable
(NS003107/NS003108)
6000i, 6100i, or 8000i remote
power signals, relay or ignition;
cable not supplied
8000i NMEA compliant compass;
cable not supplied

Scanner

Scanner communications

Scanner, using the
interconnection cable (NS003105
or NS003106)

Chassis Earth

Grounding point

Vessel's Ground using ground
wire

3.10.3.5 Earth the 10 kW scanner

The Earth bolt MUST be connected to the vessel's ground system.

Connect one end of the copper Earth plate (2) to the bolt (1) on the scanner. Connect the other end of
the Earth plate to the mounting location using the Earth bolt (3).

Northstar 10 kW Radar Installation Manual