OUTDOOR INSTALLATIONS
MODEL 133

Step 1: Remove the front (4) screws.
Step 2: Line up outdoor top vent opening over heater

vent opening.

Step 3: Lower outdoor top onto unit lining up slots in

the outdoor top with screws holes in jacket top.

Step 4: Reinstall (5) screws to secure jacket top and

outdoor top to unit.

Fig. #8114

MODELS 514 - 824

Step 1: Lower outdoor top onto unit. Position top so it

is centered on unit from side to side and front
to rear.

Step 2: Tighten the (4) screws (Shown below) until

they come in contact with the unit jacket top,
then evenly tighten all (4) screws to secure to
unit.

JACKET TOP

FASTENING

SCREW

Fig. # 8233

MODELS 926-1758

Boilers are shipped with outdoor vent terminal

factory installed.

Fig. # 8166.1

8

Fig. #RP8280.1

Outdoor Top

(Shipped Loose with Heater)

MODELS 181-401 and 182-400

Outdoor Top Installation

Step 1: Remove jacket top panel.
Step 2: Remove and discard inner stack adapter

panel.

Step 3: Install jacket top panel.
Step 4: Insert tabs of outdoor top into keyholes located

on jacket top panel (4 places). See Detail A

Step 5: Snap tabs on outdoor top into the locked

postion of the keyhole so the top will not pull
out. See Detail B

Detail A

Detail B

(Part of heater)

Fig. # 9389