Encoder module parameters setting, Figure 104 – RoboteQ AX2850 User Manual

Page 185

Advertising
background image

AX2550 Motor Controller User’s Manual

185

Encoder Setting and Testing

With this utility, the following actions can be accomplished:

•

Set and program the Encoder module’s parameters in EEPROM

•

Activate the motors in each direction at variable speed

•

View the measured encoder counts

•

View the measured encoder speed

•

View the status of the Limit Switches

The screen is composed of the following buttons and displays:

1- Setting of the Encoder’s threshold level

2- Setting of the Time Base for speed computation

3- Setting Divider for computing relative distance

4- Measure and display speed and relative distance

5- Measure and display counter values

6- Detect and display optional limit switch status

7- Start/Stop communication with controller

8- Set motor speed and direction for testing

Encoder Module Parameters Setting

The Encoder module has four programmable parameters: Two Time Bases (one for each
encoder), a Divider for computing relative distance, and the voltage threshold for discern-
ing a 0 or 1 level at the encoder’s output. In the case of the AX2550, the threshold is fixed
at 2.5V and cannot be changed.

FIGURE 104. Encoder setup and test screen on Roborun

1

2

3

7

5

4

6

7

Advertising