Operating instructions, Lighting procedure, Optional remote control – Regency P42-LP3 User Manual

Page 31: Optional wall switch, Optional wall thermostat

Advertising
background image

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

31

OPERATING

INSTRUCTIONS

1) Read and understand these instructions

before operating this appliance.

2) Check to see that all wiring is correct and

enclosed to prevent possible shock.

3) Check to ensure there are no gas leaks.

4) Make sure the glass in the door frame is

properly positioned. Never operate the ap-
pliance with the glass removed or with
broken glass.

5) Verify that the venting and cap are unob-

structed.

6) Ensure that the brick panels are installed.

7) Verify log placement. If the pilot cannot be

seen when lighting the unit, the logs have
been incorrectly positioned.

8) The unit should never be turned off, and on

again without a minimum of a 60 second
wait.

OPERATING INSTRUCTIONS

LIGHTING

PROCEDURE

IMPORTANT: Gas cock knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.

1) Turn burner OFF using "ON/OFF" switch.

OPTIONAL

REMOTE CONTROL

Use the Regency Remote Control Kit approved
for this unit. Use of other systems may void your
warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall to

install the receiver and the receptacle box
(protection from extreme heat is very im-
portant). Run wires from the fireplace to
that location. Use Thermostat Wire Table.

2) Connect the two wires to the gas valve.

See diagram below.

CAUTION

Do not wire millivolt

remote control wires

to 120V wire.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

OPTIONAL

WALL SWITCH

1) Run the supplied 15' of wire through the

right or left side gas inlet opening. Be careful
not to damage wire.

Note: We recommend a maximum of 15'

of wire but if you wish to go with a
longer run, use the Thermostat
Wire Table.

2) Connect the wire to the supplied wall switch

and install into the receptacle box.

CAUTION

Do not wire millivolt

wall switch wire

to 120V wire.

OPTIONAL

WALL THERMOSTAT

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use table below to determine the maximum wire
length.

Note: Preferable if the thermostat is in-

stalled on an interior wall.

Regency offers an optional programmable ther-
mostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

CAUTION

Do not wire millivolt

wall thermostat wires

to 120V wire.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Thermostat Wire Table

IMPORTANT

To ignite or reignite the pilot,

you must first release the

tension springs below the door.

Only when the pilot holds, without pressure
being applied to the control knob, reapply the
tension springs to the door. The unit must
not
be operated with the tension springs
unattached.