Installation, Mantel leg clearances, Mantels – Regency P42-LP3 User Manual

Page 7: Clearances

Advertising
background image

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

7

MANTEL LEG CLEARANCES

Combustible mantel leg clearances as per diagram below:

MANTELS

Because of the extreme heat this fireplace emits, the mantel clearances are critical.
Combustible mantel clearances from louver are shown in the diagram below.

Note: A non-combustible mantel may be installed at a lower height if the framing is

made of metal studs covered with a non-combustible board.

INSTALLATION

This drawing is to scale at 1:6 (one inch = 6 inches)

Mantel can be installed anywhere in shaded area using the above scale for units with the Flush
Front and with the optional Bay Front.

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant"

or the paint may discolour.

Maximum
1-1/2" projection at 2"
minimum clearance.

CLEARANCES

The clearances listed below are Minimum dis-
tances unless otherwise stated:

A major cause of chimney related fires is
failure to maintain required clearances
(air space) to combustible materials. It is
of the greatest importance that this fire-
place and vent system be installed only in
accordance with these instructions.

Clearance to Combustibles from:
Back

0"

(0mm)

Side

0"

(0mm)

Floor

0"

(0mm)

Minimum Clearance from Louver to:
Mantel

min. 7"

(177mm)

Ceiling

36"

(914mm) from top
of louvers

Side Wall

6"

(152mm)

Vent

1-1/2"

(38mm) Flex

1-1/4"

(32mm) Rigid Pipe

Alcove Clearances:
Max. Depth

36"

(914mm)

Min. Width

52"

(1321mm)

Min. Height

90"

(2286mm)

WARNING

Fire hazard is an extreme risk

if these clearances are

not adhered to.

The HeatWave Duct Kit
and the Heat Release
Kit have different clear-
ance and framing re-
quirements, check the
HeatWave and Heat
Release manual for de-
tails.

Heat Release Kit