3 technical specifications, 1 operating environment, 2 power supply specifications – RuggedCom RS900G User Manual

Page 14: 3 failsafe relay specifications

Advertising
background image

14

2008 RuggedCom Inc. All rights reserved

Rev104

3 Technical Specifications

3.1 Operating Environment

Parameter

Range

Comments

Ambient Operating Temperature

-40 to 85

°C

Ambient Temperature as

measured from a 30cm radius

surrounding the center of the

RS900G enclosure.

Ambient Relative Humidity

5% to 95%

Non-condensing

Ambient Storage Temperature

-40 to 85

°C

Operating Altitude

0 to 15240m (0 to 50000 ft)

Over temperature range of -40

to 85

°C

3.2 Power Supply Specifications

Power Supply Type

Minimum

Input

Maximum

Input

Fuse

Rating

Isolation

Maximum Power

Consumption

12 – 24 VDC

10 VDC

36 VDC

3.15A (T)

1.5 kV DC

24 VDC

18 VDC

36 VDC

3.15A (T)

1.5 kV DC

48 VDC

36 VDC

59 VDC /

72VDC

3.15A (T)

1.5 kV DC

HI (125/250 VDC)

1

HI (110/230 VAC)

1

88 VDC
85 VAC

300 VDC
265 VAC

3.15A (T)

4 kV AC 5.5

kV DC

10W


NOTES:

1.

This is the same power supply for both AC and DC.

2.

(T) denotes time-delay fuse

3.

For continued protection against risk of fire, replace only with same type and rating of fuse.

3.3 Failsafe Relay Specifications

Parameter

Value

Max Switching Voltage

30VAC, 80VDC

Rated Switching Current

0.3A @ 30VAC
1A @ 30VDC, 0.3A @ 80VDC

Figure 1 - Failsafe Relay Specification


NOTES:

1.

Resistive Load.

2.

For Class-2 circuits only.