3.4 Twisted Pair Data Port Specifications

Data Port

Media

Distance

Connector Type

10/100 Mbps

Cat 5 UTP or STP

100m

RJ45

3.5 Fiber Optical Port Specifications


For maximum flexibility RuggedCom Inc. offers a number of different transceiver choices for
Gigabit fiber optical communications. The following table details fiber optic specifications based on
the order code / transceiver selected at time of ordering.

Order

Code

Mode /

Connector

Tx

λ

λ

λ

λ

(nm)

Cable
Type

2

Tx Pwr

(dBm)

3

(Min/Max)

Rx

Sensitivity

(dBm)

3

Rx

Saturation

(dBm)

3

Typical

Distance

1

(km)

2LCMM

MM / LC

850

50

µ/125

-9.5 / -4

-20

0

0.5

2LC10

SM / LC

1310

9

µ/125

-9.5 / -3

-22

-3

10

2LC25

SM / LC

1310

9

µ/125

-5 / 0

-22

-3

25

2SC10

SM / SC

1310

9

µ/125

-10 / -3

-22

-3

10

2SC25

SM / SC

1310

9

µ/125

-7 / -3

-24

-3

25

SFP

MM / LC

850

50

µ/125

-8.5 / -4

-22

-3

0.5

SFP

SM / LC

1310

9

µ/125

-9 / -3

-24

0

10

SFP

SM / LC

1310

9

µ/125

-7 / -3

-26

-3

25

SFP

4

SM / LC

1550

9

µ/125

-5 / 0

-26

0

50

SFP

4

SM / LC

1550

9

µ/125

0 / 5

-26

0

80

SFP

SM / SC

Simplex

1310

9

µ/125

-9 / -3

-22

-3

10

SFP

4

SM / SC

Simplex

1490

9

µ/125

-9 / -3

-22

-3

10


NOTES:

1.

Maximum segment length is greatly dependent on factors such as fiber quality, and

number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.

2.

All cabling is duplex type unless otherwise specified.

3.

All optical power numbers are listed as dBm averages.

4.

These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20°C

to +85

°C operation only.