WIRING

C. Mounting controls:

A. Push Button Switch: (see fig 11)

Mount Push Button Switch in an accessible
location.

Make certain wires can be routed to Push
Button Switch.

Wire terminals must have clearance when
installed.

1. Drill 5/8" (16mm) hole.
2. Attach wires to Push Button Switch terminals (see

wiring section).

3. Install Push Button Switch through back of

mounting surface.

4. Install waterproof nut on Push Button Switch.
5. Secure in place with inner nut.

B. ME Toilet Control:

1. Cut out a hole per Fig. 12, mark

mounting holes using wall plate as guide.

2. Route wire to the toilet and control.

3. Secure control with gasket using two

screws.

C. Smart Flush Control:

1. Cut out a hole per Fig. 13, mark mounting

holes using wall plate as guide.

2. Route wire to the toilet and control.

3. Secure control using mounting

screws

Install the Warning Label (L322) where it can be
easily seen.

Mounting Remote Pump:
1. Locate remote pump between thru hull fitting and

toilet bowl.

2. Locate in an area away from berth to keep noise

level down.

3. Use Inline Strainer (optional) to avoid clogs.
4. Secure remote pump to the floor using four bolts

through the pump base.

11

Fig.11

1/4” min clearance from terminals

CUT OUT

Multifunctional Manual Switch

Fig. 12

Advertising