Plumbing – Raritan Engineering toilet User Manual

Page 9

Advertising
background image

Discharge Lines

1. Connect quality sanitation hose 1" (25 mm.) or

1 1/2”(38 mm.) discharge fitting on toilet.

2. Run hose to appropriate device (i.e.: treatment

system, holding tank, etc.).

Inlet lines

1. Connect 1/2”(13 mm.) hose to pressurized

supply or 3/4”(19 mm.) hose to remote pump

PLUMBING

B. PLUMBING

WARNING: Hazard of Flooding

Toilets mounted at or below the waterline must
have a vented loop installed in the discharge
line. The top of the vented loop must be a
minimum of 4" (10 cm.) above the waterline
at the boats greatest angle of heel (see vented
loop manufacturer’s instructions).

Sea Water Models must also have a vented
loop installed between the intake pump and
the toilet bowl.

Double clamp all below-waterline connections.

IMPORTANT

Fittings and 90° bends should be kept to a
minimum.

In-Line Strainer may be installed on Sea
Water Models per Installation
Instructions. This will prevent clogs.

Discharging untreated sewage is forbidden
in all U. S. waters within the three-mile
limit.

Thru-hull fittings and seacocks must be
installed where they are easily accessible.

Use only quality reinforced hoses such as
Raritan SH.

Secure all hoses properly.

Waterline

Remote Intake Pump Model

Mounted below Waterline

Pressurized Freshwater Model

Installed Above/below Waterline

Discharge

Pressurized

Freshwater

Source

Shut off

Valve

Waterline

remote

pump

Electroscan

Waterline

Discharge

Seacock

Waterline

Discharge

Vented

Loop

Intake Vented

Loop

Discharge

Seacock

Intake

Seacock

Electroscan

Pressurized Freshwater Model

Installed below Waterline

9

Holding Tank