Installation, Wall switch, Optional wall thermostat – Regency B36X User Manual

Page 48: Optional remote control, Included)

Advertising
background image

48

Regency Bellavista™ B36X Gas Fireplace

WALL SWITCH

(INCLUDED)

1) Run the supplied 10' of wire through the

right or left side gas inlet opening. Be
careful not to damage wire.

Note: We recommend a maximum of 10'

of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.

2) Connect the wire to the wall switch and

install into the receptacle box*. Also attach
wires to the valve as shown below.

*The receptable box (gang box) is not
supplied with the unit. Must be purchased
separately.

CAUTION

Do not wire millivolt

wall switch wire

to 120V wire.

Optional

WALL THERMOSTAT

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use table below to determine the maximum
wire length.

Note: Preferable if the thermostat is

installed on an interior wall.

Regency

®

offers an optional programmable

thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

CAUTION

Do not wire millivolt

wall thermostat wires

to 120V wire.

Thermostat Wire Table

Optional

REMOTE CONTROL

Regency offers 3 different remote control
options which are Profl ame GT, GTM and GTMF
models. See next page of all available features
of each version.

Use the Regency

®

Remote Control Kit approved

for this unit. Use of other systems may void
your warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location. Use Thermostat Wire Table.

CAUTION

Do not wire millivolt

remote control wires

to 120V wire.

2) See optional remote control instruction

manual for detailed instructions.

INSTALLATION

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

50 Ft.

16 GA.

32 Ft.

18 GA.

20 Ft.

20 GA.

12 Ft.

22 GA.

9 Ft.

Advertising