8.2 Unitary Heater Requirements

CTHN unitary heaters are typically shipped as a
burner package, fan assembly and a tube and
accessory package. The tube and accessory
packages contain enough tube, reflector and hanging
parts for one unitary CTHN heater. Elbows, u-tubes,
controls, and any other parts must be purchased
separately.

See Page 14, Figure 13 for a general overview of a
CTHN unitary heater. CTHN unitary heaters are
controlled by thermostat.

Table 5 summarizes the design requirements for a
CTHN unitary heater.

Table 5: Unitary Heater Design Requirements

Deco Grille (1' x 8' [.3 m x 2.4 m])

01363003

Bracket

01365901

End Piece

01326801

Reinforcement

01365903

Joint Piece

91406700

1' x 8' (.3 m x 2.4 m) Protective Grille

Deco Grille (2' x 4' [.6 m x 1.2 m])

01365900

Shield Frame

01370408

Reflector Side Extension 8" x 48" (20 cm x 122 cm)

01370412

Reflector Side Extension 12" x 48" (30 cm x 122 cm)

01370416

Reflector Side Extension 16" x 48" (40 cm 122 cm)

91407000

Grille, Aluminum 2' x 4' (.6 m x 1.2 m)

Protective Grille

08050001

Grille, 40" (102 cm) Protective

08050002

Protective Grille End Cap

Fan and Pump Packages

05220000

Fan Package 40-150

05221000

Fan Package 175-200

02719105

EP-100 Pump Package

02719100

EP-100 Pump

02724700

Accessory Package

02716305

EP-201 Pump Package

01312001

EP-201 Pump

01317805

Accessory Package

02712034

EP-203 Pump Package

01312002

EP-203 Pump

01317805

Accessory Package

02723014

EP-301 Pump Package 4" (10 cm)

02730101

EP-301 Pump Assembly

02730104

Accessory Package

02723016

EP-301 Pump Package 6" (15 cm)

02730101

EP-301 Pump Assembly

02730106

Accessory Package

02723034

EP-303 Pump Package 4" (10 cm)

02730103

EP-303 Pump Assembly

02730104

Accessory Package

02723036

EP-303 Pump Package 6" (15 cm)

02730103

EP-303 Pump Assembly

02730106

Accessory Package

Pump Accessories

90430600K

Pressure Switch

Starters and Contactors

10050001

Starter, 120 Vac for EP-203, 3 Ø

10050003

Starter, 120 Vac for EP-201, 1 Ø

10050008

Starter, 120 Vac for EP-301, 1 Ø

10050009

Contactor Package-
120 Vac Coil for EP-301, 230 V, 2 HP

10050010

Starter, 120 Vac for EP-303, 3 Ø

Burner Model:

CTHN-40

CTHN-60

CTHN-80

CTHN-100 CTHN-125 CTHN-150 CTHN-175 CTHN-200

Maximum Number of Burners Allowed
per Fan Assembly (P/N 05220000)

1

1

1

1

1

1

-

-

Maximum Number of Burners Allowed
per Fan Assembly (P/N 05221000)

-

-

-

-

-

-

1

1

Minimum Radiant Tube Length

10' (3 m)

20' (6 m)

20' (6 m)

30' (9 m)

40' (12 m)

40' (12 m)

50' (15 m)

50' (15 m)

Minimum Distance from Burner to Elbow or
U-Tube

10' (3 m)

10' (3 m)

10' (3 m)

15' (4.5 m) 15' (4.5 m)

20' (6 m)

20' (6 m)

20' (6 m)