Rosewill R2-RAID User Manual

Page 14

Advertising
background image

Server RAID System

[ R2-RAID ] User Manua

13

l

RAID 1 (Safe)

:It allows

the device automatically

to copy data to both

hard drives. It stores all

data in duplicate on

separate drives to p

against

rotect

data loss due to drive

failure. It provides the highest level of data protection for critical data that you

cannot afford to lose if a hard drive fails. The capacity is equal to the smaller of

the two hard drives.

If one drive fails, the SAFE volume is still usable, but it is in a vulnerable state

because its mirrored hard drive is inaccessible. When the offline drive comes

back online, the appliance begins a rebuild process immediately to restore data

redundancy.

Although the volume remains available during the rebuild process, the volume

is susceptible to data loss through damage to the remaining drive until

redundancy is restored at the end of the rebuild and verification process. Host

access takes precedence over the rebuild process. If you continue to use the

SAFE volume during the rebuild, the rebuild process will take a longer time to

complete, and the host data transfer performance will also be affected.

Drive A

250GB

Drive B

250GB

HD3206SRD

Port 0 Port 1

Equal hard drives

Drive A

250GB

Drive B

750GB

HD3206SRD

Port 0 Port 1

Safe

250GB

Safe

250GB

Unequal hard
drives

Advertising