Rosewill R2-RAID User Manual

Page 16

Advertising
background image

Server RAID System

[ R2-RAID ] User Manua

15

l

RAID / SAFE50

:It creates two

virtual volumes; one SAFE

volume and one BIG volume,

and should be used when you

need the high reliability for some

of your data but you don’t need

high reliability for the remainder

of your data. It reduces the cost of additional hard drives in operations

where non-critical data could be lost without severe consequences. If one

drive fails the SAFE volume is retrievable although the BIG volume is not.

When you replace the failed drive, the SAFE volume is automatically rebuilt

on to the replacement drive.

When using a SATA host connection, you must have a PM (Port Multiplier)

aware host adapter when using SAFE50 on the top level node of a

cascaded configuration so that ALL volumes can be detected by the host. If

your SATA host adaptor is not PM aware, then ONLY the SAFE volume will

be detected and the BIG volume will not be accessible. No such limitation

exists when using a USB host connection.

The size of the SAFE volume will be one-half of the size of one hard drive

(if they are equal) or one-half of the size of the smaller (if they are not equal).

The size of the BIG volume will be the combination of all remaining

capacities.

Drive A

250GB

Drive B

250GB

HD3206SRD

Port 0 Port 1

Safe

125GB

Equal hard drives

Drive A

250GB

Drive B

750GB

HD3206SRD

Port 0 Port 1

Big

250GB

Safe

125GB

Drive B

750GB

Unequal hard drives