Regency CLASSIC C33-2 Freestanding Gas Stove

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:

1) Clocking the appliance to ensure the correct

firing rate (rate noted on label) after 15
minutes.

2) If required, adjusting the primary air to en-

sure that the flame does not carbon. First
allow the unit to burn for 15 min. to stabilize.

3) Check for proper draft.

INSTALLATION

SAFETY LATCH

Secure door in the closed
position using the door
securing bracket and the
screw provided.

Note: Door securing

Do not put the rock wool directly on the
burner. Close the door and turn the unit on
as per lighting instructions. Watch the
flame to see if it flows smoothly around
from one end to the other. (Use Extreme
Caution and ensure proper light off of
burner.)

Diagram 3

8) If the flame hesitates at any point, check the

area of hesitation and see if there is an
ember or rock wool blocking a burner port
or ports. If so, move the obstruction and
then check the flame flow again.

DOOR HANDLE

Attach spring handle by rotating counter clock-
wise onto rod.
Ensure that the
spring fits into the
entire length of the
rod.

bracket is there for
safety.

Note: The door must be kept closed at all

times, except during maintenance.
The unit must never be operated
without the glass in the door, or
with the door open.

OPTION 1: REMOTE

CONTROL

INSTALLATION

Can be used with Options 2 or 3

but not both.

Use the Regency Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver (protection from
extreme heat is very important)
. Run
wiresfrom the fireplace to that location.
Use the Thermostat Wire Table.

2) Connect the two wires to the gas valve.

See diagram below.

CAUTION

Do not wire millivolt remote

control wires to the

120V AC wires

3) Install 3 AAA alkaline batteries in transmit-

ter and 4 AA alkaline batteries in the
receiver. Install the receiver and its cover
in the wall. Switch the remote receiver to
"remote" mode. The remote control is now
ready for operation.

OPTION 2: REMOTE

WALL SWITCH

Can be used with Options 1 or 3

but not both.

1) Run the wire through the opening in the rear

of the unit. Be careful not to damage any
wires.

Note: We recommend a maximum of 15'

of wire but if you wish to go with
a longer run use the Thermostat
Wire Table.

2) Connect the wire to the wall switch and

install into receptacle box.

OPTION 3: WALL

THERMOSTAT

INSTALLATION

Can be used with Options 1 or 2

but not both.

Regency offers an optional programmable ther-
mostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

Connect the wires as per the wiring diagram.
Use the Thermostat Wire Table to determine the
maximum wire length.

CAUTION

Do not wire millivolt wall thermo-

stat wires to the 120V AC wires

Note: Preferable if the thermostat is in-

stalled on an interior wall.

Thermostat Wire Table

CAUTION

Do not wire millivolt

wall switch for gas

appliance to the

120V AC wires

CAUTION: Any alteration to the product that
causes sooting or carboning that results in
damage to the unit is not the responsibility of the
manufacturer and will not be covered by the
warranty.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length