Safety label, Do not remove this label, Minimum clearances to combustibles – Regency C33-NG2 User Manual

Page 4

Advertising
background image

4

Regency CLASSIC C33-2 Freestanding Gas Stove

This is a copy of the label that accompanies
each CLASSIC Freestanding Gas Stove - Nat-
ural Gas
. We have printed a copy of the
contents here for your review. The safety label
is located on the back panel.

NOTE: Regency units are constantly being
improved. Check the label on the unit and if there
is a difference, the label on the unit is the correct
one.

SAFETY LABEL

For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.

For the State of Massachusetts, flexible
connectors shall not exceed 36 inches in
length.

For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.

Listed: VENTED GAS FIREPLACE HEATER
Certified for:
Report No.

CANADA and USA

476-1345-00 (Oct. 1996)

FPI Fireplace Products International Ltd.

Delta, BC, Canada

FACTORY EQUIPPED FOR NATURAL GAS:

Model C33-NG2

Minimum supply pressure 5"

WC/C.E. (1.25Kpa)

Manifold pressure High

3.8"

WC/C.E. (0.94Kpa)

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Orifice size

36

DMS

Altitude

0-2000 ft/pi

(0-610 m)

Maximum Input

33,000

BTUH

(9.67Kw/h)

Minimum Input

17,000

BTUH

(4.98Kw/h)

Factory Equipped for 0-2000 ft.

Minimum supply pressure 5"

WC/C.E. (1.25Kpa)

Manifold pressure High

3.8"

WC/C.E. (0.94Kpa)

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Orifice size

38

DMS

Altitude

2000-4500 ft/pi

(610-1370m)

Maximum Input

29,000 BTUH

(8.5Kw/h)

Minimum Input

15,300 BTUH

(4.48Kw/h)

Serial No.

201

201

HIGH ALTITUDE CONVERTED NATURAL GAS:

Model C33-NG2

Field Convertable for Altitude 2000-4500 ft.

Made in Canada

908-634b

DO NOT REMOVE THIS LABEL

Minimum Clearances to Combustibles

Back wall

Side

wall

E

A - 10"

E - 1.5"

Minimum ceiling height from top of unit: 36"/914mm

A

A

B

Back wall

Side

wall

Side

wall

This appliance must be installed in accordance with

local codes, if any; if none, follow the National Fuel

Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and

Propane Installation Codes, CSA B149.1.

FOR USE WITH GLASS DOORS CERTIFIED

WITH APPLIANCE ONLY.

This vented gas fireplace heater is

not for use with air filters.

Electrical Supply (115 V, 1.13A, 60 Hz)

Optional Fan: (Part #490-917)

Not for use with solid fuel.

Duplicate

Serial No.

B - 6"

Tested to: ANSI Z21.88b-2003/CSA 2.33b-2003,

CAN/CGA-2.17-M91