Installation Checklist.

Water Supply

■

Water heater completely filled
with water.

■

Air purged from water heater and
piping.

■

Water connections tight and
free of leaks.

Water Heater Location

■

Close to area of vent.

■

Indoors and protected from
freezing temperatures.

■

Proper clearance from combustible
surfaces observed and water heater
not installed on carpeted floor.

■

Sufficient fresh air supply for
proper operation of water heater.

■

Air supply free of corrosive
elements and flammable vapors.

■

Provisions made to protect area
from water damage.

■

Sufficient room to service heater.

■

Combustible materials, such as
clothing, cleaning materials, rags, etc.
clear of the base of the heater.

Gas Supply

■

Gas line equipped with shut-off
valve, union and sediment trap.

■

Approved pipe joint compound used.

■

Soap and water solution used to
check all connections and fittings
for possible gas leak.

■

Gas Company inspected installation
(if required).

Relief Valve

■

Temperature and Pressure Relief
Valve properly installed and
discharge line run to open drain.

■

Discharge line protected from
freezing.

Venting

■

Flue baffle properly hung in top of
heater’s flue.

■

Draft hood properly installed.

■

Vent connector(s) pitched upward

to chimney (1/4” per foot of length
minimum).

■

Vent connector(s) securely

fastened together with screws.

■

Single wall vent connector(s) at
least 6” from combustible material.