Before You Call For Service…

Problem

Possible Causes

What To Do

Rumbling noise

Scale and sediment

●

Clean tank.

in tank.

Relief valve

Pressure build up

●

This is an unacceptable condition and must be

producing popping

caused by thermal

corrected. Contact the water supplier or plumbing

noise or draining

expansion to a

contractor. on how to correct this. Do not plug the

closed system.

relief valve outlet.

Rattling noise

Internal heat trap

●

This is normal for heat trap fittings when in operation

during periods of

fittings in operation.

and does not indicate a need for service.

water usage

Not enough or

Water usage may have

●

Wait for the water heater to recover after an abnormal

no hot water

exceeded the capacity

demand.

of the water heater.

Low gas pressure.

●

Check gas supply pressure and manifold pressure.

The pilot may be out.

●

Check the pilot. If necessary, relight using the
instructions in the Lighting the water heater section
of this manual.

The gas control (thermostat)

●

See the Temperature regulation of the water heater

may be set set too low.

section of this manual.

Leaking or open hot

●

Make sure all faucets are closed.

water faucets.

Cold water inlet

●

This is normal. The colder inlet water takes longer

temperature may be

to heat.

colder during the
winter months.

Water is too hot

The gas control (thermostat)

●

See the Temperature regulation of the water heater

is set too high.

section of this manual.

CAUTION: For your safety DO NOT attempt repair of gas piping, gas control (thermostat), burners, vent

connectors or other safety devices. Refer repairs to qualified service personnel.