Raritan Engineering KX2-864 User Manual

Page 133

Advertising
background image

Chapter 7: Device Management

124

ƒ 10 Mbps/Half - Both LEDs blink

ƒ 10 Mbps/Full - Both LEDs blink

ƒ 100 Mbps/Half - Yellow LED blinks

ƒ 100 Mbps/Full - Yellow LED blinks

ƒ 1000 Mbps/Full (gigabit) - Green LED blinks

ƒ Half-duplex provides for communication in both directions, but

only one direction at a time (not simultaneously).

ƒ Full-duplex allows communication in both directions

simultaneously.

Note: Occasionally there are problems running at 10 Mbps in either
half or full duplex. If you are experiencing problems, try another
speed and duplex setting.

See

Network Speed Settings

(on page 252) for more information.

3. Select the Enable Automatic Failover checkbox to allow the

Dominion KX II to automatically recover its network connection using
a second network port if the active network port fails.

Note: Because a failover port is not activated until after a failover has
actually occurred, Raritan recommends that you not monitor the port
or monitor it only after a failover occurs.

When this option is enabled, the following two fields are used:

ƒ Ping Interval (seconds) - Ping interval determines how often the

Dominion KX II checks the status of the network path to the
designated gateway. The default ping interval is 30 seconds.

ƒ Timeout (seconds) - Timeout determines how long a designated

gateway remains unreachable via the network connection before
a fail over occurs.

Note: The ping interval and timeout can be configured to best meet
the local network conditions. The timeout should be set to allow for at
least two or more ping requests to be transmitted and responses
returned.

4. Select the Bandwidth from the following options:

ƒ 100

Megabit

ƒ 10

Megabit

ƒ 5

Megabit

ƒ 2

Megabit

ƒ 512

Kilobit

ƒ 256

Kilobit

Advertising
This manual is related to the following products: