CAN CAUSE THE CONTROLLER TO MALFUNCTION. A HIGH

QUALITY POWER CONDITIONER MUST BE INSTALLED IF THE

ABOVE CONDITIONS EXIST. MALFUNCTIONS CAUSED BY A

POOR ELECTRICAL SUPPLY ARE NOT COVERED UNDER YOUR

WARRANTY.

The controller is wired to the heater as shown in Figure 15. The model

and rating plate provides the electrical information needed to size the

complete heater branch supply.

All electrical work must be installed in accordance with the National

Electrical Code, NFPA 70.

When installed, the appliance must be electrically grounded in

accordance with local codes or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70.

DO NOT ENERGIZE THE BRANCH CIRCUIT BEFORE THE HEATER

TANK IS FILLED WITH WATER.

NOTE: This controller is Polarity Sensitive. If the Hot and Neutral Supply

Voltage is reversed, the controller will not sense flame. Verify polarity

before connecting the unit.

3. This unit may never be connected to any existing heating system or

component(s) previously used with non-potable water heating

appliance.

4. When the system requires water for space heating at temperatures

higher than required for domestic water purposes, a tempering

valve must be installed. Please refer to the installation diagrams

on pages 23 through 28 in the back of manual for suggested piping

arrangements.

HEATER WIRING

IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE

MUST BE REPLACED, IT MUST BE REPLACED WITH 105°C OR ITS

EQUIVALENT, EXCEPT IN THE BURNER HOUSING. IN THIS CASE

USE 200°C WIRE.

THE COMPUTER CONTROL REQUIRES A SOURCE OF STABLE

CLEAN ELECTRICITY FOR PROPER OPERATION. INSTALLING THE

HEATER ON A BRANCH CIRCUIT THAT HAS ELECTRONIC NOISE,

IS SUBJECT TO FLUCTUATIONS IN VOLTAGE LEVEL OR HAS AN

APPLIANCE WHICH GENERATES EMF OF RFI INTERFERENCE

FIGURE 15.