NOTE: ONCE THE THERMOSTAT TURNS OFF, A BUILT IN 5-MINUTE

DELAY PREVENTS THE SYSTEM FROM TURNING ON AGAIN.
THIS PROTECTS THE COMPRESSOR. NO ADDITIONAL TIME
DELAY RELAY IS REQUIRED. TO OVERRIDE THE 5-MINUTE DELAY
FOR INSTALLATION, PRESS THE RESET BUTTON.

3. Put the EMER-HEAT-OFF-COOL switch into

the OFF position. The air conditioning system

should turn off. The display will read SYSTEM OFF.

4. Put the EMER-HEAT-OFF-COOL switch into

the HEAT position. The display will read HEAT.

5. Press the

ٙ

button until the temperature

setting is at least 3 degrees above room

temperature. The heating system should

turn on. The fan may not turn on immediately,

depending on the fan delay built into the furnace.

The flame icon



will be displayed

( 1

st

stage heating;  2

nd

stage heating).

6. Put the EMER-HEAT-OFF-COOL switch into

the OFF position. The heating system should

turn off. The fan may continue to run for a

short period of time. The display will read

SYSTEM OFF.

7. Put the

-ON-AUTO switch into the ON

position. The blower fan should turn on.
The display will show a

and ON.

8. Put the

-ON-AUTO switch into the AUTO

position. The blower fan should turn off.