Roberts Gorden VANTAGE NP CTHN-200 User Manual

Page 13

Advertising
background image

SECTION 3: C

RITICAL

C

ONSIDERATIONS

7

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.

2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from
where the burner and burner tube connect.

*When installed in the first 10' (3 m).

FIGURE 10: 2-FOOT DECO GRILLE AND PROTECTIVE GRILLE

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

CTHN-40

5

20

41

20

13

51

104

51

CTHN-60

5

27

51

27

13

69

130

69

CTHN-80

5

30

58

30

13

76

147

76

CTHN-100

5

32

60

32

13

81

152

81

CTHN-125

5

35

65

35

13

89

165

89

CTHN-150

5

39

71

39

13

99

180

99

CTHN-175

8

44

74

44

20

112

188

112

CTHN-200

8

47

76

47

20

119

193

119

A

C

D

B

FIGURE 11: LOWER CLEARANCE SHIELD*

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

CTHN-40

5

25

22

25

13

64

56

64

CTHN-60

5

30

27

30

13

76

69

76

CTHN-80

5

37

37

37

13

94

94

94

CTHN-100

5

39

39

39

13

99

99

99

CTHN-125

5

41

41

41

13

104

104

104

CTHN-150

5

43

50

43

13

109

127

109

CTHN-175

- UNAPPROVED -

- UNAPPROVED -

CTHN-200

- UNAPPROVED -

- UNAPPROVED -

A

C

D

B

FIGURE 12: VENTING

(inches)

(centimeters)

Model

A

E

F

A

E

F

CTHN-40

14

18

18

36

46

46

CTHN-60

14

18

18

36

46

46

CTHN-80

20

24

18

51

61

46

CTHN-100

20

24

18

51

61

46

CTHN-125

20

24

18

51

61

46

CTHN-150

20

30

18

51

76

46

CTHN-175

20

30

18

51

76

46

CTHN-200

20

30

18

51

76

46

Radiant Tubes

Vent

Pipes

Unvented

Vented

A

E

F

Advertising
This manual is related to the following products: