Operating environment, 4 operating environment – RuggedCom RS416 User Manual
Page 39

Technical Specifications
39
RuggedCom
®
RuggedServer™ RS416 Family Installation Guide rev118
12-11-0006
100FX
SM/ST
1310
9/125
-15
-7
-34
-3
20
19
12-11-0005
100FX
SM/SC
1300
9/125
-15
-8
-31
-7
20
16
12-11-0004
100FX
SM/LC
1300
9/125
-15
-8
-38
-3
20
23
12-11-0031
100FX
SM/SC
1310
9/125
-5
0
-34
-3
50
29
12-11-0032
100FX
SM/LC
1310
9/125
-5
0
-35
-3
50
30
12-11-0033
100FX
SM/SC
1310
9/125
0
5
-37
0
90
42
12-11-0034
100FX
SM/LC
1310
9/125
0
5
-37
0
90
37
Table 21: Ethernet Ports – Fiber Optic Specifications
NOTES:
Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
1. All optical power numbers are listed as dBm averages.
2. All cabling is duplex type unless otherwise specified.
3. These transceivers utilize a distributed feedback (DFB) type laser and are rated
for -20
C to +85C operation only.
6.4 Operating Environment
Parameter
Range
Comments
Ambient Operating
Temperature
-40 to 85
C
Ambient Temperature
as measured from a
30cm radius
surrounding the center
of the RS1600
enclosure.
Ambient Relative Humidity
5% to 95%
Non-condensing
Ambient Storage
Temperature
-40 to 85
C
Table 22: Operating Environment