Operating environment, 4 operating environment – RuggedCom RS416 User Manual

Page 39

Advertising
background image

Technical Specifications

39

RuggedCom

®

RuggedServer™ RS416 Family Installation Guide rev118

12-11-0006

100FX

SM/ST

1310

9/125

-15

-7

-34

-3

20

19

12-11-0005

100FX

SM/SC

1300

9/125

-15

-8

-31

-7

20

16

12-11-0004

100FX

SM/LC

1300

9/125

-15

-8

-38

-3

20

23

12-11-0031

100FX

SM/SC

1310

9/125

-5

0

-34

-3

50

29

12-11-0032

100FX

SM/LC

1310

9/125

-5

0

-35

-3

50

30

12-11-0033

100FX

SM/SC

1310

9/125

0

5

-37

0

90

42

12-11-0034

100FX

SM/LC

1310

9/125

0

5

-37

0

90

37

Table 21: Ethernet Ports – Fiber Optic Specifications

NOTES:
Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
1. All optical power numbers are listed as dBm averages.
2. All cabling is duplex type unless otherwise specified.
3. These transceivers utilize a distributed feedback (DFB) type laser and are rated

for -20

C to +85C operation only.

6.4 Operating Environment

Parameter

Range

Comments

Ambient Operating

Temperature

-40 to 85

C

Ambient Temperature

as measured from a

30cm radius

surrounding the center

of the RS1600

enclosure.

Ambient Relative Humidity

5% to 95%

Non-condensing

Ambient Storage

Temperature

-40 to 85

C

Table 22: Operating Environment

Advertising