Rinnai america ff models, Optional piping for circulation systems – Rinnai Water Heater REU-V2520FFUD User Manual

Page 33

Advertising
background image

103 International Drive
Peachtree City, Georgia 30269

RINNAI WATER HEATERS

Domestic Hot Water with Circulation

1 Rinnai Water Heater

This is not an engineered drawing, it is intended only as a guide and
not as a replacement for professionally engineered project drawings.
This drawing is not intended to describe a complete system, it is up
to the contractor/engineer to determine the necessary components
for and configuration of the particular system being installed. The
drawing does not imply compliance with local building code
requirements. It is the engineer/contractor responsiblity to ensure
the installation is in accordance with all local building codes. Confer
with local building officials before installation.

Pressure Relief Valve

3/4" Ball Valve

3/4" Union

Check Valve

S

Pressure Regulator

Circulating Pump

Solenoid Valve

Boiler Drain Valve

KEY

Minimum 3/4" Hot Water

Supply Line

Building Fixture Outlets

(Optional)
2-6 Gallon
Storage Tank

(To eliminate cold water
sandwich effect caused by
frequent On/Off operation)

Pump Should be Controlled by an

Aquastat, Timer or Combination

Aquastat and Timer

Pump to be sized for 3.0 gpm flow @ 12 feet head. Flow Balancing
Valve to be adjusted to 3 GPM flow through water heater with no hot
water taps open. Pump to be of Bronze or Stainless Construction.

Cold Water Supply and Circulation Return Lines Must Be 3/4"
Tubing Throughout Circulation Loop.

Note:

Water heater outlet temperature
cannot be adjusted when
circulation pump is running.

QTY

1

1

1

Expansion Tank

Rinnai

Water Heater

Note:

PLEASE NOTE FOR RESIDENTIAL
APPLICATIONS, THIS PIPING
ARRANGEMENT REDUCES
WARRANTY TO THE FOLLOWING:

3 Years On Heat Exchanger
3 Years On Parts

Rinnai
Equipment List
(Residential and
Commercial)

Rinnai
Water Heaters
(Indoor)

MC-91 Controller
(Included)

MC-100V and BC-100V
Controllers Optional

RIK-KIT (Optional)
(3/4" Fittings Include:
2 Unions, 2 Ball Valves,
2 Drain Valves and
1 Pressure Relief Valve.)

3/4" Gas Connection

Commercial Application Warranty:

5 Years On Heat Exchanger
5 Years On Parts

Gas Supply

Venting Equipment List
(Residential and

Indoor Unit
Please Review Venting
Instructions/Guidelines for
Proper Components and
Installation.

Commercial)



Rinnai America

FF Models

I N S TA L L E R ’ S I N S TA L L AT I O N I N S T R U C T I O N S

OPTIONAL PIPING FOR CIRCULATION SYSTEMS

Advertising