Installer Notice:

These instructions must

be left with the appliance.

39) Check for gas leaks.

40) Check inlet and outlet pressures.

41) Check operation of fl ame control.

42) Check for proper fl ame appearance and

glow on logs.

29) Locate the ground lug at the receptical

box, left of the unit.

30) Connect one end of the supplied green

ground wire to the lug with the nut and
washer from the kit.

31) Install the 1/2" bushing to the heat

shield.

Ground

wire from

kit

33) Plug the DC spark generator wires to the

DC Sparker.

34) Connect the ground wire to the DC Sparker

mounting bracket.

36) Mount the heat shield to the DC Sparker.

Secure into place with the velcro, which
is provided in the kit.

Heat Shield

32) Run the other end of the ground wire

and DC spark generator wires through
the bushing on the heat shield.

38) Tie up the loose wire with the wire clip.

Chain

37a) Find a location which is not too hot and

is easy to reach for changing the battery.
Note: It should be kept away from the
chain.

37b) Recommended location to mount the
DC

Sparker.

37c) Note: Remove the bottom louver by

unscrewing the four screws located on
the hinges.

35) Install the supplied battery into the DC

Sparker Box by opening the battery
compartment.

NOTE: The battery in the DC Sparker

Box will need to be replaced annually.

Battery

Compartment

INSTALLATION