background image

May 23, 2013

7075-166C

Page 19

VOYAGEUR GRAND Wood Insert

R

Note: These are generic drawings and may not represent your specific model.

Baffle

Blanket

Latch Cam

Spacing Washers

Baffle & Blanket

Optional Blower

Chimney System

Firebrick & Ash Removal

Door & Glass Assemblies

Door Handle

Frequency

MONTHLY

or

After Every

Cord of Wood

Baffle and blanket placement is critical to

heat output, efficiency and overall life of the

unit. Make sure the baffle is pushed all of the

way to the back of the firebox and the blanket

is laying flat. Inspect baffle for cracks.

YEARLY

or

After Every

4 Cords of

Wood

Vacuum the blower impellers.

EVERY 2

MONTHS

or

After Every

4 Cords of

Wood

The chimney and chimney cap must be in-

spected for soot and creosote every two

months during the burn season or more fre-

quency if chimney exceeds or is under 14-16 ft

(4.3m-4.8m) measured from bottom of appli-

ance.
This will prevent pipe blockage, poor draft,

and chimney fires.
Always burn dry wood to help prevent cap

blockage and creosote build-up.

WEEKLY

or

After Every

25 Loads of

Wood

Ashes must be cool before you can dispose

of the ashes in a non-combustible container.
Firebrick is designed to protect your firebox.

After ashes are removed, inspect the fire-

brick and replace firebricks that are crum-

bling, cracked or broken.

WEEKLY

or

After Every

25 Loads of

Wood

Keep door and glass gasket in good shape to

maintain good burn times on a low burn setting.

To test: place a dollar bill between the stove

and door and then shut the door. If you can

pull the dollar out, remove one washer from

door handle behind latch cam and try again. If

you can still pull it out, replace the door gasket.

Check the glass frame for loose screws to

prevent air leakage. Check glass for cracks.

WEEKLY

or

After Every 25

Loads of Wood

Check the door latch for proper adjustment.

This is very important especially after the door

rope has formed to the stove face.
Check door handle for smooth cam operation.

Task

CAUTION!

Allow the appliance to completely cool

down before performing any cleaning or maintenance.

Start the first inspection after the first 2 months of use,

or if performance changes, and adjust your schedule

accordingly. Maintenance is required for safe operation

and must be performed to maintain your warranty.

G. Quick Reference Maintenance Guide