Problem

Possible Cause

Remedy

Cylinder Excessive
Drift

May be normal Operation

Check Allowable Drift rates in Service Manual

Cylinder Piston Seals
Bypass

Test to confirm and repair or replace

Damaged or Defective

Work Port Relief Valves

Check Relief Pressures. Repair or replace as

required

Main Valve Spool Leakage Confirm with tests, Repair or replace as

required

Oil Contamination

May be root cause of any internal Leakage.
Test oil and replace as required.

Related to Issues
described in Previous

section: Boom moves

under its own power

review the previous section

Cylinder Leaks at

Fittings

Loose Fittings

Check for cracks and retighten

Wrong Fittings Installed

Replace with Correct fittings

Damaged

or

defective

fitting (cracked)

due to over tightening, replace hose or

fitting

Fitting Port cracked

Repair or replace Cylinder or port

Cylinder Leaks at Rod

Faulty Seals on Cylinder
Gland

Disassemble and Replace

Damaged Cylinder Rods

Clean or Replace the Rod as required.

Cylinder Rods Bent

Determine Cause of Overload. Replace the

Rod

Cylinder Moves Wrong

Way (Not the function

that was actuated)

Incorrect Hose Routing

Check Hose Diagram in the Service Manual

and route the hoses correctly

Wire Harness improperly

Installed

Confirm incorrect placement and Re attach the

harness connectors as needed.

Operator Perception of

Correct Operation is

incorrect

Consult the Operator's Manual for Correct

operation and communicate with the Operator.

Cylinder Moves

intermittent (all

functions)

Cylinder Control Pump

Failure (all functions
affected)

Test pump to confirm. Rebuild or replace as

required.

Load Sense Signal Not

reaching the pump

Check valve Pilot pressure and Load sense

check valves.

Low Or Improper Oil in

Hydraulic system

Replace or fill as required.

Contamination of Oil

causing restricted flow in

the valve.

Replace oil, and clean components.

No voltage to Joystick

Controller

Check Fuses, wires etc and repair as required

Faulty Joystick Controller

Test then replace or repair as required.

 