WARNING:

To ensure safety and reliability, all repairs — with the
exception of the externally accessible brushes — should
be performed by a qualified service technician at a Ryobi
Authorized Service Center
to avoid risk of personal
injury.

BRUSH REPLACEMENT

See Figure 27.

Your saw has externally accessible brush assemblies that
should be periodically checked for wear.

Proceed as follows when replacement is required:

Unplug your saw.

WARNING:

Failure to unplug your saw could result in accidental
starting causing serious injury.

Remove brush cap with a screwdriver. Brush assembly
is spring loaded and will pop out when you remove
brush cap.

Remove brush assembly.

Check for wear. Replace both brushes when either has
less than 1/4 in. length of carbon remaining. Do not
replace one side without replacing the other.

Reassemble using new brush assemblies. Make sure
curvature of brush matches curvature of motor and that
brush moves freely in brush tube.

Make sure brush cap is oriented correctly (straight) and
replace.

Tighten brush cap securely. Do not overtighten.