High-speed ionization, A unique structure provides a uniform airflow, Conventional zj-fa20 – Omron Ionizer Basic Fan ZJ-FA20 User Manual

Page 3: Airflow control system (afcs)

Advertising
background image

in Fan Ionizers

Measurement Conditions
Installation distance: 300 mm
Ionization time: ±1,000 V to ±100 V
Plate monitor: 150 X 150 mm, 20 pF

Measurement Conditions
Airflow: Max.
Ionization time: ±1,000 V to ±100 V
Plate monitor: 150 X 150 mm, 20 pF

Conventional

ZJ-FA20

The airflow is dispersed,

lowering efficiency.

Engineering Data

The front louvers and

internal structure keep

the airflow uniform.

The newly developed airflow control system (AFCS) structure optimally controls the airflow of the fan

to efficiently carry the discharged ions to the target workpiece. This gives the ZJ-FA20 the highest

ionization performance in its class.

Even with the airflow at a low setting, ionization is completed in approximately 2 seconds. Small, light

workpieces are not blown away by the airflow, and static electricity is effectively neutralized.

A Unique Structure Provides a Uniform Airflow

Airflow Control System (AFCS)

High-speed Ionization

0

-300

-200

-100

0

100

ZJ-FA20

200

300

Distance direction

200

400

600

800

1 s

2 s

3 s

4 s

(mm)

(mm)

Ionization Area vs. Ionization Time

0

0.5

1

1.5

2

2.5

3

1.0

1.3

1.5

2.0

1.8

0.8

0.5

Adjustment
dial setting

Ionization time (s)

Airflow (m/s)

Airflow vs. Ionization Time

MIN:1

MAX: 5

2

3

4

Advertising