Ratings and Specifications

Dimensions

Ionizer

Ordering Information

Ionizer

Accessories (sold separafely)

AC Adapter

(Provided: UIA336-24-JR01A-998 by UNIFIVE CO., LTD.)

s

120

149

200

140

4

197.5

Mounting Hole Dimensions

(Unit: mm)

Rotation Range

220

165

8.5

12

80

80

100±0.2

15±0.2

50±0.2

Se

ven, M5

60°

60°

100 dia.

50 dia.

5.5

5.5

75

Thee

, 5.5 dia.

Note 1: Be sure to use the included AC adapter for Ionizer operation.

Note 2: Typical default settings.

Measurement location and conditions: Center of air outlet at a distance of 300 mm, with maximum fan speed

Ionization time: The time required to lower the charge from ±1,000 V to ±100 V

Ion balance measurement time: 10 s

* If an additional AC adapter is required, please contact your OMRON
sales representative

Model

Model

ZJ-FA20

Replacement Filter

Replacement Discharger Electrode

ZJ9-FL120N1

(set of 10)

ZJ9-NDT06FN1

(set of 6)

ZJ-FA20

24 VDC (See note 1.)

900 mA max. (input from included AC adapter)

±7 kV

Variable DC

1.4 to 2.3 m

3

/min (typical)

1.2 s (0.8 s with no Filter)

±10 V max.

0.01 ppm max. (measured at a distance of 50 mm from air outlet)

High-voltage output lamp: ION (yellow),

Cleaning lamp: CLEANING (orange), Power lamp: POWER (green)

Automatic ion balance adjustment, airflow adjustment,

manual ion balance adjustment

Operating and storage: 0 to 50°C (with no icing or condensation)

Operating: 35% to 65%, storage: 35% to 85% (with no condensation)

Approx. 2.0 kg

Unit: ABS, Discharger: Tungsten, stand: SPCC

Instruction sheet, AC adapter, warning labels (2 types),

FG connection cable (2 m)

Item Model

Power supply voltage

Current consumption

Discharge voltage

Discharge method

Airflow (m

3

/min.)

Ionization time

(See note 2.)

Ion balance

(See note 2.)

Amount of generated ozone

Indicators

Main functions

Ambient temperature range

Ambient humidity range

Weight (packed state)

Materials

Accessories

100 to 240 VAC, 50/60 Hz

AC240V: 115VA MAX

240 VAC: 115 VA max.

24 VDC

1.5 A max.

0 to 40°C

35% to 85% (with no condensation)

Approx. 175 g (excluding power cable)

43.8 X 28 X 95.9 (W X D X H) mm

Item

Input voltage

Power consumption

Output voltage

Output current

Ambient temperature range

Ambient humidity range

Weight

Dimensions

60°

120°

120°