3

2.

HOW TO OBT

AIN A CORRECT

MEASUREMENT

The body fat monitor is a monitoring device. It should be used

at a fixed point in time and with a fixed period between two

measurements. For instance: once a week on a Sunday

morning. With this in mind, please find in paragraph 2.1 a

table with recommended times for measurement.

There are conditions that are not suitable for taking a body fat

measurement. There are also some exceptions that are

excluded for taking a body fat measurement. This is explained

in paragraph 2.2 and 2.3. This chapter will end with some

recommendation (paragraph 2.4) before taking a measurement.

2.1 Recommended times for measurement

Understanding the

normal changes in

your body fat per-

centage can help you

in preventing or

reducing obesity

.

Being aware of the

times when the body

fat percentages shift

within your own

daily schedule will

assist you in obtain-

ing an accurate trend

of your body fat. It is

recommended to use

this unit in the same

environment and

same daily circum-

stances. (See chart)

2.2 The conditions or circumstances NOT suitable for a

correct measurement

If a measurement is made under the following physical

conditions, the measured body fat percentage may differ

significantly from the actual one because the water content

in the body changes.

2.3 Exceptions

In some cases, the measured body fat percentage may differ

too much from the actual body fat percentage. These excep-

tions are the people for who measurements may vary due to

consistently changing amounts of water and tissue density

within their bodies.

2.4 Recommendations for taking a measurement

If the palms of your hands are dry or the temperature of your

palms or the grip of the electrodes are extremely cool, stable

measurement is impossible, which may lead to display error

indication or inaccurate results.

Please pay special attention in winter because the air is dry

and/or the temperature is low

.

Conditions

Actions

Hands are dry

.

S

lightly moisten hands with

a wet towel, then measure.

When you hold the grip

W

arm the grip electrodes by

electrodes, they feel cold.

leaving the unit in a warm

room for approximately ten

minutes.

Y

our body and hands are cold

W

arm your hands by

due to the blood not circulating

immersing in warm water

well.

or staying in a warm room.

Start the measurement

again.

Daily activities

Waking up

Breakfast

Lunch

Taking bath and dinner

Going to bed

2 hours

2 hours

2 hours

After waking up

Before lunch and about 2 hours or

more after breakfast

In the afternoon about 2 hours or

more after lunch and before taking

bath or dinner

Before going to bed and about 2

hours or more after taking a bath

or dinner

Recommended time zone

Recommended time zone

Recommended time zone

Recommended time zone

Children of

growing stage

Elderly people

and women after

menopause

Those having

swelling

Patients of

osteoporosis

having very

low bone density

Bodybuilders or

professional

atheltes

Patients under-

going dialysis

Pregnant women

People with

a fever

Immediately after

vigorous exercise

Immediately after

taking bath or sauna

After drinking

much alcohol

After taking a large amount

of water or after a meal

English

2

Thank you for purchasing this OMRON BF306 Body Fat

Monitor

. T

o

ensure proper and safe use of this unit, please take

a few minutes to carefully read this instruction manual.

Please keep this instruction manual on hand and in a safe

place for future reference.

T

ABLE OF CONTENTS

1

Safety precautions and storage

. . . . . . . . . . . . . . . . . . . . .

2

1.1

Important safety instructions

. . . . . . . . . . . . . . . . . . .

2

1.2

Care and storage

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1.3

Features of this product

. . . . . . . . . . . . . . . . . . . . . . .

2

2

H

ow to obtain a correct measurement?

. . . . . . . . . . . . . .

3

2.1

Recommended times for measurement

. . . . . . . . . . .

3

2.2

The conditions or circumstances that are

not suitable for a correct measurement

. . . . . . . . . . .

3

2.3

Exceptions

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

2.4

Recommendations for taking a measurement

. . . . . .

3

3

O

peration and usage of the Omron BF 306

body fat monitor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

3.1

Description of the unit

. . . . . . . . . . . . . . . . . . . . . . . .

4

3.2

Battery insertion and replacement

. . . . . . . . . . . . . . .

4

3.3

Setting personal data before taking

a measurement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

3.4

T

o take a measurement

. . . . . . . . . . . . . . . . . . . . . . . .

5

3.5

Setting and using personal memory number

. . . . . .

6

3.6

T

o change any values

. . . . . . . . . . . . . . . . . . . . . . . . .

6

4

H

ow to interpret measured results

. . . . . . . . . . . . . . . . . .

6

4.1

B

MI (Body Mass Index) value

. . . . . . . . . . . . . . . . . . .

6

4.2

Body fat percentage

. . . . . . . . . . . . . . . . . . . . . . . . . .

6

5

T

roubleshooting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

5.1

Possible causes of inaccurate measurements

. . . . . .

7

5.2

Explanation of error codes

. . . . . . . . . . . . . . . . . . . . .

7

5.3

T

roubleshooting

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

5.4

Important information for users

. . . . . . . . . . . . . . . . .

8

6

Specifications

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

1.

SAFETY PRECAUTIONS AND STORAGE

1.1 Important safety instructions

Please read the following instructions

carefully

,

as they contain

important information concerning the setting up, use and care

of your new Body Fat Monitor

.

Keep this manual for future reference.

Do not disassemble the body fat monitor

. Apart from the

batteries, it contains no user serviceable parts.

Do not subject the device to strong shocks.

Although there are no known side effects, the body fat monitor

must

NOT

be used under the following conditions:

• During an acute contagious disease;

By persons with medical implants (e.g. pacemakers);

By persons with any heart disease. Use the monitor after

consultation with your doctor;

Never use it in combination with artificial heart-lung and

other electronic life support systems;

Never use it in combination with an electrocardiograph and

other (portable) electronic medical devices.

Do not use the body fat monitor in a highly humid environ-

ment such as sauna or while you are in a bath or in a shower

.

Never submerse in water

.

Do not let unattended children or infirm persons have access

to the unit.

If you discover that the body fat monitor is damaged or does

not operate properly

, switch it off immediately and stop using

it. An authorized dealer using only original OMRON spare

parts must carry out any repairs. Any part of the unit may only

be repaired or replaced by the Omron Service representative.

Please note that this device is only intended to measure the

body composition

1.2 Care and Storage

Clean the main unit with a soft dry cloth. If the main unit is

heavily stained, wipe it with a cloth lightly dampened with

water or detergent, then wipe it dry with a dry cloth.

A

void an excessive amount of water

, this can cause internal

damage.

Do not wipe the unit with benzene, gasoline; paint

thinner

, alcohol, or other volatile detergents.

1.3 Features of the product

Accurate measurement

The body fat percentage is measured based on the electric

resistance and the personal data such as height, weight, age

and gender

. The measured results are closely correlated with

the “underwater weighing method” and

the DEXA (Dual

Energy X-ray Absorbtiometry) m

e

thod, which are said to be

the standard measurements methods for measuring the body

fat percentage.

Measurement is fast and simple

After setting the data, body fat mass can be measured by sim-

ply holding the grip electrodes and pushing the Start button.

T

h

e

measured results are displayed approximately 7

seconds

after the Start screen is displayed.

Large and clear displays

The easy to read large digital and graphic displays can be

understood at a glance. The measured results based on body

fat percentage and on BMI calculations are displayed alternate-

ly

, as well as their interpretations.

Memory

The memory can store the personal data (height, weight, age

and gender) of up to 9 people simultaneously

.

Small, lightweight and portable