AFTER OPERATION

Switch off pressing ON/OFF button.

Unplug from mains supply outlet.

Rewind the cord pressing cord rewind button. Hold the plug when rewinding, do not allow the cord to get entangled and the plug

to bump the casing.

You can store the vacuum cleaner in both horizontal and vertical positions. The hose can remain fitted, but please be careful not

to bend it too much.
Horizontal storage:

insert the handle located in back part of brush – nozzle into the handle socket at the backside of the vacuum cleaner near the

supply cord inlet.

Vertical storage:

insert brush – nozzle on telescope pipe,

insert the handle into the handle socket at the bottom of the vacuum cleaner next to front wheel.

FULL DUST COMPARTMENT INDICATOR

Full bag indicator glowing (red colour), when the nozzle or brush is above the cleaned surface, informs us that it is necessary to

empty dust compartment.

Full bag indicator can activate also in case of blocked sucking hose or one of connected accessories. In such case, remove the

hose from front lid and clean the hose and connected accessories.

DUST COMPARTMENT – emptying, cleaning

The vacuum cleaner is equipped with a dust compartment, which is a removable part of the vacuum cleaner

When removing dust compartment switch off and unplug from mains supply outlet.

Remove the dust compartment from the vacuum cleaner. In order to do it:

press the dust compartment button, simultaneously removing all this part of the vacuum cleaner,

place the compartment ovr the dust bin.

After pressing the compartment button, the bottom of the compartment shall open and the content shall fall

into the dust bin.

After emptying the dust bin lock the bottom and insert the compartment into the vacuum cleaner.

VACUUM CLEANER FILTERS

The vacuum cleaner is equipped with the filter system:

Inlet-air filter cone.

Motor protecting filter.

Outlet-air filter.

Inlet-air filter cone – cleaning

The filter is located inside the dust compartment. In order to exchange it:

Empty the dust compartment (see the item.

DUST COMPARTMENT – emptying, cleaning).

Turn the inlet filter cone in direction of

„1” and remove it in your direction „2”.

Clean the cone, wash it, rinse it and dry thoroughly.

In case of inlet cone damage replace it with a new one.

ATTENTION! Turn your atttention to the basket at the bottom of the cone flange. Do not loose it.
After inlet –air cone cleaning:

Insert the cone into the cone socjet, so that two protrusions

„A” located on the flange got under the locker

„B” in the compartment casing

Press the cone strong and turn it in direction of

„3”, until it runs, sou will hear characteristic clicking sound,

close (lock the bottom of the compartment).

Insert all the unit into the vacuum cleaner chamber (see the item

DUST COMPARTMENT – emptying,

cleaning).

HEPA motor protecing filter – exchange

Svislé

uskladnění

horizontal

storage

vertical

storage

Remove the dust compartmentu (see the item

DUST COMPARTMENT – emptying, cleaning).

After pulling out the locker of the filter grade, remove HEPA fliter.

Rinse the filter and dry it thoroughly.

In case of filter damage replace it with a new one.

Attention! HEPA motor protecting filter should be replaced with a new one twice a Lear and

etery time when it is damaged.

Lock the grate with the filter.

OUTLET FILTER - EXCHANGE

Switch off the vacuum cleaner and unplug it from the mains supply outlet.

Drag out the filter outlet and remove it upwards.

Remove the grid with outlet filter from the filter socket.

Remove the outlet filter from the grid hooks.

Wash, rinse and dry carefully the outlet filter.

Insert a new one in case it is damaged, assembling carefully at the grid hooks.

Insert the assembled grid into the filter socket.

Insert the filter protection and lock it.

CLEANING AND MAINTENANCE

Remember to check if the vacuum cleaner is unplugged before cleaning and maintenance. Clean the casing and bag chamber with damp cloth (it can be

wet with wash – up liquid) dry or wipe up to get it dry. Do not use abrasive agents or dissolvent. Vacuum the nozzle-brush, small brush or special acces-

sories with a gap nozzle from time to time.

WHAT TO DO WHEN…?

The vacuum cleaner was switched off during operation by over-heating protection:

switch off the appliance, unplug it from the mains supply outlet and wait approximately 40 minutes before you switch it on again,

remove the dust compartment, empty it and clean the cone of the inlet-air filter and HEPA outlet-air filter.


Do not assemble dust compartment section until the vacuum cleaner cools down:

check and clean the accessories: sucking hose, pipes, nozzle and brushes,

re-assemble the vacuum cleaner and start it up,

if the over-heating protection repeats to often, or you can not switch on the vacuum cleaner after cooling, bring your vacuum cleaner to service desk.

Advertising